The resistance limits for footwear and wrist strap tests are controlled by the DIP switches located on the left side of the Desco™ Combo Tester X3. Use the following tables for the DIP switch settings and their corresponding test values.
Default settings are in Bold.
Wrist Strap Resistance
DIP switches 5 and 6 control the HIGH test limit.
The LOW limit for the wrist strap is set to 750 Kilohms (7.5 x 105) and cannot be modified by the user.
Switch 5 | Switch 6 | HIGH Limit Resistance |
OFF | OFF | Wrist Strap Test Disabled |
ON | ON | 10 Megohms (1 x 107) |
ON | OFF | 35 Megohms (3.5 x 107) |
DIP switch 5 must be ON (default setting) for the wrist strap test to be active. The wrist strap test will be disabled if DIP switch 5 is set to OFF.
Related
The resistance limits for the shoe grounder and wrist strap tests are controlled by the DIP switches located on the left side of the Desco™ Combo Tester X3. Use the following tables for the DIP switch settings and their corresponding test values.
Default settings are in Bold.
Footwear Resistance
DIP switches 1 and 2 control the HIGH test limit.
Switch 1 | Switch 2 | HIGH Limit Resistance |
ON | ON | 10 Megohms (1 x 107) |
OFF | OFF | 35 Megohms (3.5 x 107) |
ON | OFF | 100 Megohms (1 x 108) |
OFF | ON | 1 Gigohm (1 x 109) |
DIP switches 3 and 4 control the LOW test limit.
Switch 1 | Switch 2 | LOW Limit Resistance |
OFF | OFF | footwear test disabled |
ON | OFF | 100 Kilohms (1 x 105) |
OFF | ON | 750 Kilohms (7.5 x 105) |
Related
Reviews